Central air conditioning repair and maintenance

新闻banner
Your current location: Home >> News >> Zhiming News

Contact UsContact Us

Jiangsu Zhiming HVAC Equipment Engineering Co., Lt

Manager Hu: +86 13962631222 (Business Manager)

Yu Haibin: +86 15062669873 (after-sales service)

Tel: +86 0512-57553334

Mail box: admin@jszmnt.com

The website is www.jszmnt.cn

Add: No. 18 Yucheng South Road, Kunshan City, Suzhou City, Jiangsu Province

Dimensions of the central air conditioning ceiling

2020-06-08 11:33:21
Times

Now there are many families want to install central air conditioning, it is said that the central air conditioning can purify the indoor air with fresh air system, but the central installation and need to pay attention to a problem, Kunshan central air conditioning installation ceiling size should be left how much? In general, under what circumstances is it recommended to install central air conditioning? Let's take a look!



First, the height of the central air conditioning indoor unit


Dimensions of the central air conditioning ceiling


There are many kinds of height of this central air conditioning indoor unit, and the thinnest central air conditioning indoor unit I have seen is 18cm; Also seen particularly thick central air conditioning indoor unit is 55cm. Therefore, there are really many kinds of central air conditioning indoor unit sizes, which we can choose according to needs.


 

1.jpg



The thickness of the indoor unit of the central air conditioner used in the family, the most conventional size is 20 cm, and the size of the indoor unit of this kind of central air conditioner is 200×450x450, 200x700x450, 200x1100x450 and so on. 200 here is its thickness. In addition, now in order to meet the needs of the family, there has been an ultra-thin type of central air conditioning indoor unit, that is, as said above, personally seen the thinnest central air conditioning indoor unit size, the thickness is 18cm.


Let's take a conventional 200 mm thick indoor unit with central air conditioning as an example. To install this indoor unit with central air conditioning, the space we need is about 250 mm. Because there has to be a boom here, and then there has to be some amount of air conditioning, so he needs another five centimeters of wealth.



Second, indoor how high it is recommended to install central air conditioning


The indoor net control height of our new commercial housing is basically about two meters and seven meters. We take 2 meters 7 as an example, the air conditioning indoor unit uses a conventional 200mm thick indoor unit, then with the ceiling at least to 250mm. The indoor headroom is 2700mm, and then subtract 250mm, then the net control level of 2450mm is left at the end.


The clearance level of 2450mm is actually acceptable. This is based on some of our personal habits, some people will feel that the net control level is a little low, it will feel very depressed, and some people do not feel. In fact, you may not know that the current indoor net control elevation design is about 2700mm, which is determined according to some habits of most people, because this height is the most suitable and comfortable.


Therefore, like a standard high-rise building, if the installation of air conditioning, personally feel that it is not suitable. But if it doesn't feel relevant, of course it can be installed.



Third, install the central air conditioning ceiling size


First of all, the steps of the maintenance and construction of the central air conditioning should be to install the pipes of the central air conditioning, requiring them to be installed as close to the top surface as possible, and then determine the height of the ceiling according to the low position of the air conditioning. Assume that the thickness of the indoor unit of the central air conditioner is 190mm, and the ceiling height is generally increased by 50-60mm on the basis of the thickness of the internal unit of the air conditioner you purchase. If the thickness of the central air conditioning is only 181mm, it is enough to reserve 250mm for the ceiling. Not any house is suitable for the installation of central air conditioning, the choice of central air conditioning depends on the room, according to the structure of their own houses and the expected decoration effect of the choice of air conditioning. If the height of the house is less than 2.7 meters, the height will be less than 2.4 meters after the installation of central air conditioning, and the person will feel "top-heavy", affecting the living comfort. Even if the central air conditioning is installed, the local ceiling method should be used to avoid a large area of pressure.